BioSure Compact Hygiene Systems

WDS Water Disinfection System

A compact range of point-of-use water disinfection systems that convert clean tap water into ozonated water directly at the outlet. The WDS series includes multiple models for different flow rates, from compact rinse points through to higher-flow commercial hygiene applications.

  • Point-of-use water treatment
  • Flow-start operation
  • Electrolytic ozone generation
  • Replaceable EOG cell cartridge
  • Multiple models for different flow rates
Best for Rinse points and wash stations

For sites that need treated water directly at the outlet rather than a handheld spray bottle.

Model range From 60 to 600 mg/hr

The WDS range covers compact and higher-flow commercial point-of-use applications.

Not a portable spray product. If the task is surface spraying without plumbing connection, use the Ozone Spray Bottle Pro.
BioSure WDS3000X Water Disinfection System

Product overview

On-demand ozonated water at the point of use

The WDS Water Disinfection System range is designed for applications where the water itself needs to be treated as it is used, such as rinse points, wash stations, beverage areas and selected hygiene-focused outlets.

Instead of preparing a separate chemical solution, WDS units use electrolytic ozone generation to produce ozonated water directly from clean tap water as it flows through the system.

In-line installation Designed for integration into a water line or selected point-of-use outlet.
Flow-start design The system is intended to operate when water flows through the unit.
Replaceable cartridge Uses a replaceable electrolytic ozone generation cell cartridge for ongoing operation.

How it works

Connect. Flow. Use.

The WDS range is designed to make point-of-use water treatment practical for commercial environments without the complexity of a large engineered ozone system.

1 Connect to the water line The unit is installed in-line or at a suitable point-of-use outlet, depending on the application and plumbing arrangement.
2 Water flow activates treatment As water passes through the unit, the system generates ozonated water using electrolytic ozone technology.
3 Use treated water immediately The treated water is used directly for the selected rinse, wash or hygiene routine at the outlet.
Ozcon guidance: WDS systems should be selected according to flow rate, water quality, pressure, installation point, contact time and hygiene objective. We recommend checking the application before specifying a model.

Application fit

Where WDS fits best

WDS is best suited to water-use points where treated water is required directly from the outlet. It is not the same product as the handheld spray bottle.

Rinse points and wash stationsFor selected commercial outlets where treated water is required as part of the daily hygiene routine.
Catering and food preparation areasFor hygiene-focused water use points, equipment rinsing and controlled wash applications.
Beverage and bar areasFor selected beverage-related waterlines, rinse points and back-of-house hygiene applications.
Beer line hygiene supportBioSure positions WDS systems for beer line cleaning and hygiene, subject to site procedure and suitability review.
Small commercial water applicationsFor outlets where compact footprint and point-of-use treatment are preferred over a larger ozone system.
Higher-flow outlet applicationsFor larger commercial points, WDS6000X provides the highest flow capability in the range.

Why choose this system?

Practical benefits for commercial water-use points

Reduced chemical handling Helps reduce reliance on conventional chemical sanitation methods in suitable applications.
On-demand operation Ozonated water is generated as needed, directly from the water flowing through the system.
Multiple capacities The range includes 60, 120, 300 and 600 mg/hr models for different outlet requirements.
User display and controls Selected WDS models are designed with user-facing display and controls for easier day-to-day operation.
Maintenance features BioSure highlights intelligent self-booster and smart self-cleaning maintenance functions.
Compact commercial footprint A smaller point-of-use format for selected outlets where a full engineered system is unnecessary.

Responsible positioning

Commercial hygiene support, selected with care

Manufacturer documentation The BioSure catalogue positions the WDS range for food handling, beverage waterlines, sanitation and hygiene maintenance applications.
Correct specification matters Water quality, pressure, flow rate and the intended hygiene routine should be checked before selecting a model.
UK wording matters Ozcon will avoid broad or unsupported sanitation claims and will assess the intended application before supply.
Important: Performance, sanitation, food-contact or health-related claims should be supported by the relevant documentation and checked against the intended UK application. The WDS system should be used as part of an appropriate hygiene procedure, not as a standalone guarantee of compliance.

Key details

WDS series datasheet

The WDS range is available in four model sizes, from compact point-of-use systems through to higher-flow commercial units. Model selection should be based on flow rate, connection size, water quality, pressure and the required level of treated water performance at the outlet.

ModelsWDS600X / WDS1200X / WDS3000X / WDS6000X
Ozone output60–600 mg/hr
Flow range60–4600 LPH
Aqueous ozoneUp to 1.0–2.6 ppm
Specification WDS600X WDS1200X WDS3000X WDS6000X
Model code EOS7210-BX EOS7211-BX EOS7177-PQX EOS7178-PQX
Electrolytic ozone production 60 mg/hr ±10% 120 mg/hr ±10% 300 mg/hr ±10% 600 mg/hr ±10%
Aqueous O₃ concentration Up to 1.0 ppm Up to 2.0 ppm Up to 2.6 ppm Up to 2.6 ppm
Ozone cartridge lifespan 1000 operating hours 1000 operating hours 1000 operating hours 1000 operating hours
Nominal operating flow rate 60–1650 LPH
(0.3–7.3 GPM)
60–1650 LPH
(0.3–7.3 GPM)
100–2300 LPH
(0.4–10.1 GPM)
200–4600 LPH
(0.9–20.2 GPM)
Nominal operating flow pressure 0.5–7.0 kg/cm²
(7.1–100 psi)
0.5–7.0 kg/cm²
(7.1–100 psi)
0.5–7.0 kg/cm²
(7.1–100 psi)
0.5–7.0 kg/cm²
(7.1–100 psi)
Waterline connections Inlet: 1/2 inch female swivel nut adapter
Outlet: 1/2 inch male thread pipe fitting
Inlet: 1/2 inch female swivel nut adapter
Outlet: 1/2 inch male thread pipe fitting
Inlet: 3/4 inch male thread pipe fitting
Outlet: 3/4 inch male thread pipe fitting
Inlet: 1 inch male thread pipe fitting
Outlet: 1 inch male thread pipe fitting
Working water quality Cold clean tap water Cold clean tap water Cold clean tap water Cold clean tap water
Dimensions
(W × D × H)
117.8 × 72.9 × 123.1 mm 117.8 × 72.9 × 148.2 mm 140 × 128.5 × 210.5 mm 168 × 146.5 × 273.9 mm
Net weight 394 g 473 g 1.3 kg 3.0 kg
Power supply 100–240 V AC, 50/60 Hz
Adaptor output: 24 V DC / 1.0 A
100–240 V AC, 50/60 Hz
Adaptor output: 5–15 V DC / 2.0 A
100–240 V AC, 50/60 Hz
Adaptor output: 24 V DC / 4.0 A
AC 100–120 V or 220–240 V, 50/60 Hz
Adaptor output: 5–16 V DC / 10.5 A
Electrical rating 15 W 30 W 96 W 170 W
Application capacity Up to 700 lbs/day
daily ice production
Up to 1800 lbs/day
daily ice production
Application dependent High-flow applications
Operating note: Cold clean tap water should be below 30°C, filtered to ≤1 μm, with TDS ≥60 ppm and hardness below 250 ppm as CaCO₃. For X-suffix models, regular acid cleaning may be required depending on actual water conditions. Final model selection should be based on site flow rate, water chemistry, pressure and intended hygiene routine.

Request a quote

Check which WDS model is suitable for your outlet.

Tell us where the system will be installed, the available flow rate, water pressure, water quality and intended hygiene routine. Ozcon can advise whether WDS600X, WDS1200X, WDS3000X, WDS6000X or a different ozone solution is the better fit.

Request a Quote