Engineered ozone systems for borehole and well water treatment, supporting microbial control, iron and manganese oxidation, odour reduction, biofilm management and improved water quality.
Borehole water can be a valuable water source for farms, estates, food production sites, process facilities, bottled water operations and private supplies. However, groundwater quality can vary significantly depending on geology, seasonal conditions, abstraction rate and local contamination risks.
Common issues include microbial contamination, iron and manganese staining, rotten egg odours from sulphur compounds, turbidity, organic matter, taste and odour problems, and biofilm growth inside pipework or tanks.
Ozone can be used as a powerful on-site oxidising treatment step. In borehole water applications, it is normally applied through a properly designed water injection and contact system, followed by filtration or downstream treatment where required. The best results come from treating ozone as part of a complete process, not simply adding a generator to a pipe.
Ozone is strongest where oxidation and disinfection are the main treatment objectives. In many borehole systems, it works best when combined with contact time, filtration, monitoring and suitable downstream treatment.
Borehole water can contain bacteria, viruses and other microorganisms, especially where well integrity, surface ingress, storage tanks or distribution pipework create contamination risks.
Elevated iron and manganese can cause staining, metallic taste, discolouration and operational issues. Ozone can oxidise these metals so they can be removed by suitable filtration.
Hydrogen sulphide and related sulphur compounds can create strong, unpleasant odours in borehole water. Ozone can oxidise these compounds and help reduce odour at source.
Cloudy or muddy water may be caused by suspended solids, sediment or oxidised minerals. Ozone can support particle aggregation and oxidation, but filtration is usually essential.
Natural organic matter and other dissolved contaminants can affect taste, odour and colour. Ozone can oxidise many organic compounds and support improved water aesthetics.
Biofilm can build up in well components, storage tanks, pipework and distribution loops. Ozone can help control microbial growth and oxidise organic layers when correctly dosed.
A borehole ozone system is more than an ozone generator. Reliable performance depends on ozone generation, injection, mixing, contact time, off-gas control, filtration and monitoring working together.
Ozone is generated on site and injected into the borehole water stream using a venturi, injection pump or dedicated contact arrangement. The water then requires sufficient contact time before filtration or use.
Typical equipmentOzone generator, oxygen source, injection system, static mixer, contact tank or contact loop, filtration stage, sensors, control panel and off-gas destructor where required.
Best suited toIron and manganese oxidation, microbial control, odour reduction, organic oxidation, tank recirculation and process water pre-treatment.
Ozone must be controlled safely. Borehole systems should consider operator exposure, room ventilation, off-gas management, flow interlocks, residual monitoring and ozone-compatible materials.
Control optionsDissolved ozone monitoring, ORP, flow switch, pressure switch, timers, PLC signals, alarms and automatic shutdowns.
Site supportOzcon can support specification, supply, commissioning guidance and operator training. Installation, electrical works, plumbing and civil works are normally handled by the client or their appointed contractor unless agreed separately.
Correct sizing depends on the borehole water quality and the required outcome. A small change in flow rate, iron level, organic load, temperature or contact time can significantly change the required ozone capacity.
Iron, manganese, pH, turbidity, hardness, alkalinity, organics, microbiology, sulphides, nitrates and any known contaminants.
Borehole yield, treatment flow rate, peak demand, daily usage, storage volume and whether the process is continuous or batch.
Disinfection, iron oxidation, odour control, process water improvement, tank recirculation, filtration support or reuse preparation.
Filters, UV, softeners, carbon, chlorination, storage tanks, pressure vessels, pumps and any current compliance requirements.
Available pipe length, tank volume, recirculation option, pressure and the time available before filtration or point of use.
Space, ventilation, drainage, power supply, control integration, materials compatibility, operator access and maintenance requirements.
We assess water analysis, contamination risks, flow rate and the actual treatment objective.
We decide whether inline injection, tank recirculation, contact vessel or a hybrid arrangement is most suitable.
We size the generator, injection hardware, oxygen supply, contact stage, filtration interface and controls.
Commissioning and testing are used to refine setpoints and confirm the system is working as intended.
Ozone is most valuable where water quality problems can be solved through controlled oxidation, disinfection and integration with the right downstream treatment.
Ozone is produced as needed from oxygen or air, reducing reliance on stored oxidising chemicals.
Ozone can oxidise iron, manganese, sulphur compounds, microorganisms and selected organic contaminants.
Once contaminants are oxidised, downstream filtration can remove precipitated metals and suspended material.
Ozone decomposes back to oxygen, which can be useful where long-lasting chemical residuals are not desired.
Correctly applied ozonated water can support biofilm management in compatible pipework, tanks and recirculation systems.
Systems can be designed with sensors, interlocks, alarms and automation for safer, more repeatable operation.
Ozcon can recommend individual components or a complete ozone treatment package depending on the water quality, flow rate, treatment target and level of automation required.
Skid-mounted systems for dissolving ozone into water with controlled injection, mixing, contact time and monitoring.
Explore systems →Oxygen-fed ozone generators for continuous-duty water treatment, process water and industrial applications.
View generators →Dissolved ozone sensors, ORP control, ambient ozone monitors, off-gas destructors and system interlocks.
View equipment →Ozone can be highly effective, but only when the application is properly defined. Before recommending a system, Ozcon will normally check the following points.
pH, alkalinity, temperature, organic load, iron, manganese and suspended solids all affect ozone demand and system performance.
Oxidised iron, manganese and suspended solids normally need to be removed through suitable filtration after ozone treatment.
Ozone needs sufficient time to react. Some applications require a contact tank, pressure vessel, static mixer or recirculation loop.
Ozone can damage unsuitable plastics, elastomers and metals. Seals, pipework, valves and tanks should be checked before installation.
Drinking water, private water supplies and food production sites may have testing, validation and compliance requirements that must be considered.
Nitrates, salts, hardness, some pesticides, heavy metals and PFAS may require specialist treatment beyond ozone alone.
Ozone can support disinfection and oxidation, but drinking water suitability depends on the complete treatment system, water analysis, contact time, filtration, monitoring and compliance testing. It should not be specified from generator output alone.
Ozone can oxidise iron and manganese so they precipitate from the water. These oxidised particles then need to be removed by suitable filtration.
In many cases, ozone can oxidise hydrogen sulphide and related sulphur compounds that cause rotten egg odours. The final system may also require filtration, degassing or polishing depending on the water quality.
They do different jobs. UV is commonly used for disinfection but does not oxidise iron, manganese, sulphur odours or organic matter in the same way. Ozone can provide oxidation and disinfection support, while UV may still be useful as part of a wider treatment train.
We normally need a recent water analysis, flow rate, daily demand, treatment objective, existing treatment equipment, available contact time, site layout and whether the water is for drinking, process use, irrigation or another application.
Ozcon typically provides system design, specification, supply, commissioning support and technical guidance. Site installation, electrical works, plumbing and civil works are normally completed by the client or their appointed contractor unless agreed separately.
Share your water analysis, flow rate, treatment objective and existing system layout. Ozcon will review the duty and recommend a practical ozone treatment configuration.